Single and 3 Phase Oil Filled Padmount Transformers for 50/60 Hz

A generic image

Medium Voltage Oil-Filled Transformers

Medium voltage (MV) oil-filled transformers are essential components in power distribution networks, military, industrial plants, and commercial facilities. They operate between 2.4 kV and 34.5 kV (sometimes up to 69 kV) and use mineral oil or biodegradable FR-3 esters for insulation and cooling.

1. Key Features & Applications

  • Utility Networks: e.g., 13.8 kV -> 480 V
  • Industrial Plants: 13.8 kV -> 480 V
  • Commercial Buildings: Reliable power for data centers, hospitals
  • Renewables: Grid interface (e.g., 34.5 kV collection systems)

Typical Ratings

  • Voltage: 5 kV – 35 kV (ANSI/IEEE)
  • Power: 500 kVA – 20 MVA
  • Cooling: ONAN, ONAF, KNAN

2. Design & Construction

A. Core & Windings

  • Core: Grain-oriented silicon steel
  • Insulation: Kraft paper + oil
  • Windings: MV-rated primary (e.g., 15 kV, 95 kV BIL), LV secondary (e.g., 480 V)

B. Tank & Cooling

  • Sealed tank: Free-breathing or conservator
  • Cooling: Radiators/fins, nitrogen blanket

C. Bushings & Accessories

  • Tap Changers: NLTC (manual), OLTC (automatic)
  • Monitoring: Sudden pressure relay, Buchholz relay, temperature gauges

3. US Standards & Compliance

  • ANSI/IEEE C57.12.00 – General requirements
  • IEEE C57.12.90 – Test codes
  • NEMA TR-1 – Transformer standards
  • DOE 2016 – Efficiency rules
  • EPA & NFPA 70 – Environmental & fire safety

4. Oil-Filled vs. Dry-Type Comparison

Feature Oil-Filled Dry-Type
Cooling Superior (oil-cooled) Air-cooled
Voltage Up to 345 kV Usually ≤ 35 kV
Lifespan 30+ years 20–30 years
Cost Lower for large units Higher per kVA
Maintenance Requires oil care Minimal
Fire Risk Higher Lower

5. Maintenance Overview

A. Common Issues

  • Oil degradation, overheating, bushing failures, internal faults

B. Best Practices

  • DGA testing (dissolved gas analysis)
  • Oil filtration, infrared scans, leak checks
  • Resistance testing (windings & bushings)

6. Future Trends

  • Biodegradable ester fluids
  • IoT-based smart monitoring
  • Modular, space-saving substation designs

In Summary

Medium voltage oil-filled transformers are essential for reliable, efficient power delivery across the U.S. With proper maintenance and evolving smart technologies, they remain a top choice for utilities, industries, and renewable integrations.

Displaying 1 to 12 (of 12 Products)
Part Number * KVA Rating Frequency Phase High Voltage (HV) Low Voltage (LV) Specifications Qty. Price
CWS-100KVA1P-12.47K 0 100 KVA 60 Hz 1 Phase 12,470 Volts 240/120 Volts   In Stock: 0
$56,050.00
Buy Now
CWS-150KVA3P-12.47D 0 150 KVA 60 Hz 3 Phase 12,470 Volts 240/120 Volts Spec. Document In Stock: 0
$29,875.00
Buy Now
CWS-167KVA1P-12.47K 0 167 KVA 60 Hz 1 Phase 12,470 Volts 240/120 Volts   In Stock: 0
$70,250.00
Buy Now
CWS-225KVA3P-0.48 0 225 KVA 60 Hz 3 Phase 480 Volts 240/120 Volts Spec. Document In Stock: 0
$61,395.00
Buy Now
CWS-300-3P-12.4-208Y 0 300 KVA 60 Hz 3 Phase 12,470 Volts 208/120 Volts Spec. Document In Stock: 0
Buy Now
CWS-500KVA3P-12.47-208 0 500 KVA 60 Hz 3 Phase 12,470 Volts 208/120 Volts   In Stock: 0
$130,757.00
Buy Now
CWS-500KVA3P-12.47-480 0 500 KVA 60 Hz 3 Phase 12,470 Volts 480/277 Volts   In Stock: 0
$130,757.00
Buy Now
CWS-500KVA3P-13.2K 0 500 KVA 60 Hz 3 Phase 13,200 Volts 480/277 Volts   In Stock: 0
$131,000.00
Buy Now
CWS-500KVA3P-34.5K 0 500 KVA 60 Hz 3 Phase 34,500 Volts 480/277 Volts   In Stock: 0
$131,000.00
Buy Now
CWS-50KVA1P-12.47K 0 50 KVA 60 Hz 1 Phase 12,470 Volts 240/120 Volts   In Stock: 0
$48,475.00
Buy Now
CWS-750-3P-12.4-480Y 0 750 KVA 60 Hz 3 Phase 12,470 Volts 480/277 Volts Spec. Document In Stock: 0
Buy Now
CWS-75KVA1P-12.47K 0 75 KVA 60 Hz 1 Phase 12,470 Volts 240/120 Volts   In Stock: 0
$50,875.00
Buy Now
Displaying 1 to 12 (of 12 Products)